RADICAL TRANSPARENCY

PCB QC Report Sample:
What the 11-Page Inspection Report Shows

Review a real 11-page outgoing inspection report for a 92-piece bare PCB lot. The PDF shows the stated requirements, measured values, acceptance decisions, inspector approval, and lot traceability fields used for this sample shipment.

View The PCB Report Sample
UL E315835
FR-4 TG
94V-0
RoHS Compliant

Inside This PCB QC Report Sample

The embedded PDF is a bare PCB outgoing report. It links the lot identity and compliance certificate to the actual dimensional, electrical, microsection, solderability, and thermal-stress records used for the final acceptance decision.

Outgoing_Audit_Report_Sample.pdf (11 Pages) Full Screen

Need More Test Reports?

Enter your email to request comprehensive quality testing data, including IQC, IPQC, FQC, and advanced reliability test reports for your industry.

Secure & Spam-free.

What the 11 Pages Document

This sample records the final inspection of one 92-piece bare PCB lot dated May 20, 2025. The outgoing audit uses AQL 0.4 where sampling applies and records the requirement, actual reading, and acceptance decision for each check.

1. Compliance and lot identity

The certificate of compliance identifies UL file E315835, FR-4 TG material, 94V-0 flame class, RoHS status, lot quantity, date code, and ship date.

2. Outgoing audit summary

The audit sheet consolidates material, plating, solder mask, legend, circuitry, hole, profile, reliability, electrical, visual, and environmental checks with an ACC result.

3. Dimensional records

Dedicated pages record finished hole diameters, 56 drawing dimensions, overall board thickness, and component-side and solder-side trace width and spacing.

4. Electrical and microsection evidence

The lot received a 100% electrical test. Microsection records document PTH copper thickness, hole-wall roughness, layer copper, finished surface copper, and solder mask thickness.

5. Reliability checks

The report includes solderability and thermal-stress conditions, observed results, final acceptance, inspector, approver, and test date.

How to Read This PCB Inspection Sample

The figures below are transcribed from the embedded report so buyers can understand the document before opening the full PDF.

CheckRequirement in this sampleRecorded result
Finished board thickness1.60 +/- 0.16 mm1.58-1.67 mm, accepted
PTH copper thickness20 um minimum at a point, 25 um average25.3-29.9 um, accepted
Solder mask thickness15 um minimum29.8-29.9 um, accepted
Trace width and spacingDrawing values with +/-20% tolerance0.19-0.21 mm readings, accepted
Ionic contamination6.4 ug NaCl/sq. in. maximum0.020 ug NaCl/sq. in., accepted
Electrical test100% of the 92-board lot92 passed, 0 failed
SolderabilityMore than 95% good wetting at 260 +/- 5 CEven solder on both sides, accepted
Thermal stress288 +/- 5 C, three 10-second cyclesNo listed defects observed, accepted

Scope note: This is a bare PCB outgoing inspection example, not a universal specification or a PCBA functional-test report. Inspection criteria and deliverables must follow the applicable drawing, finish, industry standard, purchase order, and agreed quality plan for each project.

Tests Shown in This Sample

The sample combines measured results and signed acceptance records rather than relying on a single pass/fail statement.

Dimensional & Hole Measurement

Finished dimensions and drilled-hole readings are compared with the drawing requirements and recorded per sample.

100% Electrical Test

The electrical report records continuity, insulation, test voltage, sample size, passed quantity, and failed quantity.

Microsection Analysis

Destructive testing to verify plating thickness, hole wall integrity, and layer registration.

Solderability & Thermal Stress

Solderability and thermal-stress pages state the test conditions, observed results, acceptance decision, and sign-off.

Full Traceability for Critical Industries

Quality documentation should match the risks and acceptance criteria of the project. We retain batch-specific inspection records according to our quality procedures and agreed customer requirements, so the shipment can be traced back to its lot, date code, measured results, and approval record.See our inspection methods.

Contact Us to Start Your Project